VİDALI PRES(dekantör)
SIYIRICILAR DÖNER KÖPRÜLÜ SIYIRICI
DİP SIYIRICI
SENSÖRLER
P&I DİYAGRAMI OLUŞTURULMASI PIPE AND INSTRUMENTS (BORU VE ENSTRÜMAN DİYAGRAMI)
P&I DİYAGRAMI ÖNCESİ YAPILMASI GEREKEN İŞLER ATIKSUYUN YAPISI BELİRLENMELİ, ARITILABİLİRLİK ÇALIŞMASI YAPILMALI (LABORATUVAR ÖLÇEĞİNDE) DEBİ, KİRLİLİK YÜKLERİ, ARITMA KADEMELERİ BELİRLENMELİ, ARITMA TESİSİ AKIM ŞEMASI OLUŞTURULMALI, KULLANILACAK TANK VE HAVUZ BOYUTLARI HESAPLANMALI, ARITMA TESİSİ PLAN VE KESİTİ ÇİZİLMELİ ARITMA TESİSİ HİDROLİK PROFİLİ OLUŞTURULMALI, MÜMKÜN İSE TESİSİN ÜÇ BOYUTLU ÇİZİMİ YAPILMALI, KULLANILACAK EKİPMANLAR TESPİT EDİLMELİ, HESABI YAPILMALI VE SEÇİMİ YAPILMALI, BORU TİPLERİ SEÇİLMELİ,
P&I DİYAGRAMINDA KODLAMALAR BORU ÖZELLİKLERİ YAZILIRKEN SIRASI İLE 1.BORU UZUNLUĞU (METRE OLARAK YAZILIR), 2.BORU ÇAPI (PE, PVC, HDPE VB. PLASTİK BORULARDA ÇAP MİLİMETRE CİNSİNDEN YAZILIR, ÇELİK BORULARDA ÇAP İNÇ (“) CİNSİNDEN YAZILIR 3.BORU TİPİ YAZILR PLASTİK VE TÜREVİ BORULAR İÇİN ÖRNEK YAZILIM: L=10 M Q150 PVC, L=5M Q50 PVC ÇELİK BORULAR İÇİN ÖRNEK YAZILIM L=105M 6” GA, L=19M 12” PÇ
EKİPMAN VE ÜNİTE KODLAMALARI ÜNİTE VE EKİPMAN KODLAMALARI 101 NUMARADAN BAŞLAR AKIŞ HATLARINA GÖRE 100 BİRİM ARTIRILARAK 201, 301..... DEVAM EDER AYNI HAT ÜZERİNDEKİ ÜNİTELER 101, 102, 103, 104..... OLARAK DEVAM EDER FARKLI HATTA GEÇİLDİĞİNDE KODLAMA KADEMESİ 100 BİRİM ARTTIRILARAK 201, 202, 203.... OLARAK DEVAM EDER, BETONARME HAVUZLAR H-101, H-102, H-201.... OLARAK KODLANIR, PLASTİK, ÇELİK VB. TANKLAR T-101, T-102, T-103, T-201, T-301.... OLARAK KODLANIR, POMPALAR P-101, P-102, P-103, P-201, P-301.... OLARALAK KODLANIR, KARIŞTIRICILAR K-101, K-102, K-103, K-201, K-301... OLARAK KODLANIR, MAKİNELER M-101, M-102, M-103, M-201, M-301...OLARAK KODLANIR,
VANALAR V-101, V-102, V-103, V-201, V-301.... OLARAK KODLANIR BLOWER VE KOMPRESÖRLER C-101, C-102, C-103, C-201, C-301... OLARAK KODLANIR (C=COMPRESSOR) AERATÖRLER (A=AERATOR) A-101, A-102, A-103, A-201, A-301... OLARAK KODLANIR EKİPMANLAR YEDEKLİ KULLANILIYORSA 101A/S, 102A/S, 103A/S, 201A/S, 301A/S OLARAK KODLANIR.BİR ÜST NUMARAYA GEÇMEZ. SEVİYE KONTROL “LC”= “LEVEL KONTROL” OLARAK KODLANIR, “HL” = “HİGH LEVEL, ÜST SEVİYE”, “LL” = “LOW LEVEL, ALT SEVİYE”. LC 101, LC 102, LC 103, LC 201, LC 301... OLARAK KODLANIR. PH KONTROLÜ “PHC” = “PH CONTROL, PH KONTROLÜ” ANLAMINA GELİR, PH 101, PH 102, PH 103, PH 201, PH 301... OLARAK KODLANIR
ÖRNEK SÜT MAMULLERİ ÜRETİM TESİSİ ATIKSULARI ATIKSU ÖZELLİKLERİ KOI: 6,300 MG/L YAĞ VE GRES: 750 MG/L AKM: 1,500 MG/L İSTENİLEN ARITILMIŞ SU STANDARDI (KANALA DEŞARJ STANDARDI) KOI: 4,000 MG/L YAĞ VE GRES: 250 MG/L AKM: 500 MG/L
ÖN GÖRÜLEN ARITMA ÜNİTELERİ OTOMATİK TEMİZLEMELİ IZGARA, DENGELEME HAVUZU, FLOKÜLASYON (KİMYASAL ARITMA) ÜNİTESİ, DAF (ÇÖZÜZÜNMÜŞ HAVA FLOTASYONU) ÜNİTESİ, DEŞARJ ROGARI ÇAMUR YOĞUNLAŞTIRMA ÜNİTESİ, ÇAMUR SUSUZLAŞTIRMA ÜNİTESİ
AKIM ŞEMASI
ÜÇ BOYUTLU GÖRÜNÜM
ARITMA TESİSİ YERLEŞİ PLANI
HİDROLİK PROFİL
P&I DİYAGRAMI